Product Details:
Pressure Range (cm H2O) | 4 to 20 hPa |
Weight (gm) | <1.6 kg / <2.4 kg with humidifier |
Dimension | 220 X 194 X 112 mm (without humidifier) 313 X 194 X 112(with humidifier) |
Operating Mode | Continous |
Usage | Hosptal |
Screen Type | LcD |
Additional Information:
Product Details:
Parameter Measures | SpO2 + Pulse Rate |
Display Type | Dual Color OLED Display |
Model Name/Number | EMD 101 |
Features | Portable, Digital |
Usage/Application | Hospital Use |
Pulse Rate Range | 30-240 BPM |
General Description
The children’s fingertip pulse oximeter features in small volume, low power consumption, convenient operation
and portability. it is only necessary for patient to put one finger into fingertip photoelectric sensor for diagnosis,
for patient to put one screen will directly show measured value of hemoglobinsaturation. it has been proved in
clinical experiments that it prossesses rather high precision and repeatability.
Detailed descriptions of product functions:
· Display Type: OLED display
· Sp02 Measurement range : 70% — 99% Accuracy: ±2% on the stage of 80% — 99%; ±3% on the stage of 70% — 79%; Below 70% no requirement Resolution: ±1%
· PR:Measurement range: 30BPM – 240BPM Accuracy:± BPM or ±t1%(the larger one)
· Pi index:measurement scope: 0-20 (optional) Power : reachargable lithium battery
· Power consumption: below 30mA
· Automatic power-off the product shuts off by it self when no finger is in the product ≥8 seconds
Dimension : 44mm x 26.5mm
Operation Environment:Operation Temprerature:5° — 40°
Storage Temperature:-l0° — 40°
Ambient Humidity: 15%-80% on operation
10% —80% in storage
Air Pressure : 70kPa – 106kPa
· Declaration:EMC of this product comply with IEC60601 1-2 standard.
· Measurement Performance in Low Perfusion Condition : required test equipment (BIO-TEK INDEX Pulse Oximeter tester) could measure the available pulse wave with the amplitude of 6% of the simulation pulse wave amplitude.
· Interference Resistance Capacity against Ambient Light : Device : works normally when BIO-TEK INDEX Pulse Oximeter tester exerts interfering signal test
Product Details:
Parameter Measures | SpO2 + Pulse Rate |
Display Type | Color TFT Display |
Model Name/Number | EMD120 |
Warranty | 12 Months |
Features | Portable |
Usage/Application | Hospital Use |
Features
· Displays Sp02 and pulse waveforms
· Plethysmograph graph displayed for improved performance
· Color TFT Display with Multi-Directional Views
· Brightness control
· Low power consumption with low battery alarm on display
· Adult Sp02 sensor Included
· Optional sensors for neonatal and pediatric applications
· Data analysis software
· Programmable alarms
· AC charger or from USB port
· Programmable display
· Flash memory with 24 data read back
· Pulse sound indication
· 1 Year Manufactures Warranty
· Great product for hospitals, health care providers, physicians, nurse practitioners
Product Details:
Brand | ASCO |
Flow Rate | 5 LPM |
Type Of Equipment | Oxygen concentrator |
Product Details:
Usage/Application | Hospital |
Brand | Apothecaries |
Usage | BP measure |
Product Details:
Brand | BMC |
Pressure Range (cm H2O) | 4-25 |
Operating Mode | continuous |
Weight | 1.5 kg 2.5 kg (with the humidifier) |
Dimensions | 170 mm x 180 mm x 118 mm 290 mm x 180 mm x 134 mm (with the humidifier) |
Product Details:
Parameter Measures | SpO2 + Pulse Rate |
Display Type | Dual Color OLED Display |
Model Name/Number | EMD102 |
Display Mode | 6 display modes |
Features | Digital, Portable |
Usage/Application | Hospital Use |
Two parameters:SPO2, Pulse Rate Sp02 Waveform
Beep Alarm and with Perfusion Index
COLOR OLED display, four direction adjustable
Technical Parameters
· Integrated with Sp02 probe and processing display module.
· Application: hospital, home, community medical treatment, sports healthcare etc.
· Can measure SpO2 and pulse rate accurately
· Sp02 and pulse rate display, pulse rate waveform and bar graph display
· Battery voltage low indication
· Four directions and six modes
· Screen brightness adjustable
· Low power consumption; shut off automatically when no signal
· Small volume(57(L) x 31(L) x 32(H) mm)light, convenient to carry
· Display mode:0.96″ double colour OLED display, screen resolution: 1% for Sp02 , l bpm for pulse rate
· Accuracy: ±2%(70%-100%), unspecified (<70%) for Sp02 , ±2bpm or ±2%(select larger) for pulse rate.
· Power supply: 1.5V(AAA size) alkaline batteries can work 20 hours continously.
· Interference resistance capacity against ambient light and measurement performance at low perfusion
Product Details:
Parameter Measures | SpO2 + Pulse Rate |
Model Name/Number | EMD 110 |
Oximeter Accuracy | +-2% |
Features | Portable |
Usage/Application | Hospital Use |
Pulse Rate Range | 30 - 250 BPM |
Technical Parameters
· Measurement of Sp02
· Measuring range: 0-100
· Accuracy: When the Sp02 measure range is 70%-100%,
the permission of absolute error is ±2%
· Below 70% unspecified
· Measurement of pulse rate
· Measure range: 30bpm-250bpm
· Accuracy: ±2 bpm or ±2%(select larger)
· Measurement of PI
· Measure range: 0-20%
· When the PI measure range is 1%-20% the permission of absolute error is ±0.2%
· When the PI measure range is 0%-0.9%, the permission of absolute error is ±0.2%
· Resolution: Sp02: 1% Pulse rate: lbpm PI: 0.1%
· Measurement performance in weak filling condition
· Sp02 and pulse rate value can be shown correctly when pulse-filling ratio is 0.4%.
· Sp02 error is ±4%; pulse rate error is ±2bpm or ±2%(select larger) Resistance to surrounding light
· The deviation between the value measured in the condition of man-made light or indoor
natural light that of darkroom is less than ±1%
· Operating Voltage: Internal power supply: 3.6 V DC-4.2V DC
· Exterior alternating current supply: 100-240VAC 50/60 Hz
Features
Sp02 value display
Pulse rate value display, bar graph display
PI value display
Pulse waveform display
Battery power display
With the functions of multiuser and review Screen brightness can be adjusted
Volume can be adjusted
Product Details:
Parameter Measures | SpO2 + Pulse Rate + NIBP |
Display Type | LED Display |
Model Name/Number | EMD 130 |
Weight | 1.5 kg |
Features | Portable |
Usage/Application | Hospital Use |
Features
· 2.8″ Height brightness TFT LCD display
· High brightness LED display of NIBP, Sp02 and pulse rate
· Memory: Built-in flash memory
· Up to 2000 groups NIBP data storage and Sp02 data upto 48 hours
· Visual and Audio alarms, adjustable
· Audio volume adjustable
· Built-in rechargeable Li-Polimer
Specifications NIBP
· Method: Oscillometry
· Mode: Manual/Auto/Continuous
· Measurement Range: 25-260 mmHg
· Resolution: 1 mmHg : NIBP Accuracy: ±5mmHg
· Alarm: SYS/DIA/MAP
SpO2
· Measurement Range: 0%-100%
· Resolution: 1%
· Accuracy ±2%(70%-100%), 0%-69% unspecified
· Alann range: 0-100%
Pulse Rate
· Measurement Range: 10-270mmHg
· Resolution: lbpm
· Accuracy ±2bpm or ±2(select larger)
Dimension(LxWxH)
· 190x160x244(mm)
Net Weight
· 1.5Kg
Product Details:
Parameter Measures | SpO2 + Pulse Rate + NIBP |
Model Name/Number | EMD 131 |
Oximeter Accuracy | +-2% |
Features | Portable |
Usage/Application | Hospital Use |
Measurement Range | 25-260 mmHg |
Features
· High Brightness LED Display of NIBP, SpO2 and Pulse Rate Wave with Temperature
· Visual and Audio Alarms,Adjustable
· Audio Volume Adjustable
· Built-in-reachargable battery
Specifications
· Method: Oscillometry
· Mode: Manual/Auto/Continuous
· Measurement Range: 25-260 mmHg
· Resolution: lmm Hg : NIBP Accuracy: ±5mmHg
· Alarm: SYS/DIA/MAP
SpO 2
· Measurement Range: 0%-100%
· Resolution: 1%
· Accuracy ±2%(70%-100%), 0%-69% unspecified
· Alarm range: 0-100%
Pulse Rate
· Measurement Range: 10-270mmHg
· Resolution: lbpm
· Accuracy ±2bpm or ±2(select larger)
Temperature
Product Details:
Brand | ASCO |
Usage/Application | Hospital |
Material | Plastic |
Color | White |
Thermometer Type | Infrared Thermometers |
Accuracy | 0.5% |